BZM MODEL

SYSTEM OVERVIEW
The system has a series of steps through which incoming effluent undergoes to attain desired effluent quality by time of discharge summarized below.
Primary Screening: Traps indigestible waste from incoming sewage before entering primary tank.
Primary Settlement: provides effective primary settlement of effluent and also allows for anaerobic digestion to take place. Anaerobic & aerobic microbial culture and required enzymes are dosed and mixed with the effluent at this stage.
Equalization: This is buffering process for peak influent loading into the plant providing desired stabilization on aeration process. provided to balance / smooth high levels of variations in the influent wastewater flows, expected during the peak flow periods.
Aeration: Introduction of air into the bioreactors breaking down the organic matter by aerobic digestion. The system combines both anaerobic and aerobic digestion to ensure optimal breakdown of organic matter before discharge into the environment.
Secondary Settlement/Clarification: allows for settlement of treated effluent from the bioreactors through aeration. Disinfection disinfectant dosing system is required to disinfect the effluent before is released to the drainage.
Chlorination: Final treatment stage for effluent killing any present microorganisms before discharge to environment.
UV light disinfection lamp:
Desludging: returns settled sludge from the clarifier back to primary treatment zone from where treatment cycle can begin.
Control system: to automize the treatment process.

BZM MODEL SIZING INFORMATION

We are flexible to install any size from 4000 liters depending on the population and wastewater generated daily.

MODELVOLUMEMAX FLOW/DAYEST. POPULATION
BZM4-5PE4M3500L5 PE
BZM6-15PE6M31500L15 PE
BZM8-20PE8M32000L20 PE
BZM12-30PE12M33000L30 PE
BZM16-40PE16M34000L40 PE
BZM24-60PE24M36000L60 PE
BZM36-90PE36M39000L90 PE
BZM40-100PE40M310000L100 PE
BZM48-120PE48M312000L120 PE

LARGE SYSTEMS ARE AVAILABLE WITH ORDERS

BENEFITS OF THE BZM MODEL SYTEM

Key benefits of the BZM Model system

  • The system provides treated water as per NEMA Schedule 6 Guidelines which is suitable for irrigation use, and cleaning of cars, pavements and disposed to storm water drains.
  • NEMA Effluent Treatment Guidelines (see table below)
  • Low electricity consumption.
  • Quiet operation.
  • No need of separating grey water from black water in case of sewer wastewater treatment.
  • The system eliminates use of an exhauster as is the case of septic tanks. Additionally, there is no need to worry about soak pit in the area filled with clay soils.
ParameterGuide Value
pH6.5-8.5
Biological Oxygen Demand (5 days at 20 oC)30 (mg/L) max
Chemical Oxygen Demand50 (mg/L) max
Suspended Solids30 (mg/L) max
Ammonia –NH4 + Nitrate-N03 + Nitrite –N02100 (mg/L) max
Total Dissolved Solids1200 (mg/L) max
E. coli0/100 ML
Total Coliform1000/100 ML
ColorLess than 40 hazens

APPLICABLE TO ALL KINDS OF WASTE QUALITY

1. residential, apartments, institutions to municipal sewage.
2. Industrial wastewater, i.e. chemical, pharmaceutical, food processing, slaughter houses and other industries.
3. it is suitable for high-protein and high-starch wastewater generated by food.
4. industries such as freezing plants, canning plants, and beverage plants.
5. wastewater generated by poultry farms and slaughterhouses.
6. wastewater purification in alcohol production industries such as beer, malt, and rice wine factories.
7. wastewater treatment generated by high-concentration alcohol-containing chemical plants.
8. car wash wastewater

You cannot copy content of this page